The Gecko in.touch 3 is a smart connectivity module that links your spa’s control system to your home network and the Gecko App. Below are the key technical details to help installers and advanced users understand its hardware, power, and environmental requirements.

Hardware components

The in.touch 3 system is made up of two modules that work together to provide remote connectivity:

Component

Description

CO module (Spa module)

Installed under the spa skirt and connected to the Gecko control pack via the CO port. Communicates wirelessly with the EN module.

EN module (Home module)

Connects to your home router using an Ethernet cable. Provides Wi-Fi connectivity to the cloud and communicates with the CO module via RF signal.

Each module includes LED indicators for quick diagnostics of power, pairing, and connectivity states

Power and connection

  • Power source (EN module): External power supply included (connects to 120V or 220V AC outlet)

  • Router connection: 100 Mbps RJ45 (LAN) Ethernet port

  • Cable length included: 3 ft (0.9 m) Ethernet cable

  • Communication frequency:

    • 915 MHz for North America (FCC models)

    • 868 MHz for Europe (ETSI models)

Compatibility

  • Compatible spa packs: in.yj, in.ye, in.yt (versions 2 and higher)

  • Compatible apps: Gecko App (iOS 8.0+ / Android 2.3+)

  • Compatible Wi-Fi networks: Standard home routers supporting 2.4 GHz band (Port 10022 open)

Physical dimensions and weight

Module

Dimensions (mm)

Dimensions (in)

Weight

in.touch 3 CO module (Spa)

86 × 70 × 23

3.39 × 2.76 × 0.91

320.5 g

in.touch 3+ CO module (Spa)

136 × 99 × 43

5.31 × 3.87 × 1.65

-

EN module (Home)

82 × 70 × 24

3.23 × 2.76 × 0.94

63.5 g

Environmental specifications

Condition

Specification

Operating temperature

–4°F (–20°C) to 140°F (60°C)

Storage temperature

–22°F (–30°C) to 185°F (85°C)

Humidity

Up to 85% non-condensing

Waterproof rating

IPX5 (resistant to water jets)

Installation clearances & RF compliance

To ensure optimal signal strength and compliance with RF exposure standards:

  • Install the CO module at least 12 in (30 cm) away from any metal components or foil insulation

  • Maintain a minimum 8 in (20 cm) separation from people during operation

  • Do not co-locate or operate with other antennas or transmitters

  • Power off before connecting or servicing the unit

Certifications and safety

  • Regulatory compliance: FCC (North America) / ETSI (Europe)

  • Electrical safety: Must be connected to the Gecko control pack using manufacturer-specified cables only

  • Servicing: No user-serviceable parts inside, refer servicing to qualified personnel