Overview
The Gecko in.touch 3 is a smart connectivity module that links your spa’s control system to your home network and the Gecko App. Below are the key technical details to help installers and advanced users understand its hardware, power, and environmental requirements.
Hardware components
The in.touch 3 system is made up of two modules that work together to provide remote connectivity:
Component | Description |
CO module (Spa module) | Installed under the spa skirt and connected to the Gecko control pack via the CO port. Communicates wirelessly with the EN module. |
EN module (Home module) | Connects to your home router using an Ethernet cable. Provides Wi-Fi connectivity to the cloud and communicates with the CO module via RF signal. |
Each module includes LED indicators for quick diagnostics of power, pairing, and connectivity states
Power and connection
Power source (EN module): External power supply included (connects to 120V or 220V AC outlet)
Router connection: 100 Mbps RJ45 (LAN) Ethernet port
Cable length included: 3 ft (0.9 m) Ethernet cable
Communication frequency:
915 MHz for North America (FCC models)
868 MHz for Europe (ETSI models)
Compatibility
Compatible spa packs: in.yj, in.ye, in.yt (versions 2 and higher)
Compatible apps: Gecko App (iOS 8.0+ / Android 2.3+)
Compatible Wi-Fi networks: Standard home routers supporting 2.4 GHz band (Port 10022 open)
Physical dimensions and weight
Module | Dimensions (mm) | Dimensions (in) | Weight |
in.touch 3 CO module (Spa) | 86 × 70 × 23 | 3.39 × 2.76 × 0.91 | 320.5 g |
in.touch 3+ CO module (Spa) | 136 × 99 × 43 | 5.31 × 3.87 × 1.65 | - |
EN module (Home) | 82 × 70 × 24 | 3.23 × 2.76 × 0.94 | 63.5 g |
Environmental specifications
Condition | Specification |
Operating temperature | –4°F (–20°C) to 140°F (60°C) |
Storage temperature | –22°F (–30°C) to 185°F (85°C) |
Humidity | Up to 85% non-condensing |
Waterproof rating | IPX5 (resistant to water jets) |
Installation clearances & RF compliance
To ensure optimal signal strength and compliance with RF exposure standards:
Install the CO module at least 12 in (30 cm) away from any metal components or foil insulation
Maintain a minimum 8 in (20 cm) separation from people during operation
Do not co-locate or operate with other antennas or transmitters
Power off before connecting or servicing the unit
Certifications and safety
Regulatory compliance: FCC (North America) / ETSI (Europe)
Electrical safety: Must be connected to the Gecko control pack using manufacturer-specified cables only
Servicing: No user-serviceable parts inside, refer servicing to qualified personnel